3-CONDUCTOR 7/32'' VS 5/16'' VS 15/32''
- PROPERITIES
Cable Diameter 7/32''(5.6mm) 5/16(8.0mm) 15/32''(11.8mm)
Minimum Sheave Diameter 11''(280mm) 16''(400mm) 23''(590mm)
Cable Stretcch Coefficient
ft/Kft/Klbs(m/Km/5KN) 2.2(2.5) 1.2(1.35) 0.76(0.85) - ELECTRICAL
Maximum Conductor Voltage 1,000VAC 1,000VAC 1,000VAC
Conductor AWG Rating 24 14 17
Minimum Insulation Resistance
MΩ/Kft(MΩ/Km) 1,640(500) 1,640(500) 1,640(500) - MECHANICAL
Cable Breaking Strength
Ends Fixed 5622 lbs(28KN) 10125 lbs(55KN) 10125 lbs(55KN)
MAximum Suggested Working Tension 4050 lbs(21KN) 7425 lbs(55KN) 14175 lbs(55KN)
Number and Size Wires
Inner Armor 12 wires 0.79mm 12 wires 0.81mm 24 wires 1.0mm
Outer Armor 18 wires 0.79mm 18 wires 1.11mm 24wires 1.26mm
Cable Type |
Main Description |
Cable Weight |
||||||
Temp Rating |
Insulation Type |
Insulation Thickness |
Copper Construction |
Conductor Resistance |
Cap.Typical |
O.D Inmm |
Lbs/Kft/Kg/Km |
|
W3FP-5.6 3*0.24 |
450℉ |
FEP |
0.0087in |
7*0.21mm |
25.9Ω/Kft |
51.8pF/ft |
0.22 |
97 |
W3FP-8.0 3*0.5 |
450℉ |
FEP |
0.017in |
7*0.30mm |
11Ω/Kft |
51.8pF/ft |
0.32 |
179 |
W3FP-11.8 3*1.12 |
450℉ |
FEP |
0.033in |
19*0.28mm |
9.4Ω/Kft |
39.6pF/ft |
0.46 |
355 |